Avidyne Entegra EXP5000 Instrucciones de operaciones Pagina 71

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 90
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 70
Invalid Sensors and Error Conditions
600-00157-000 Rev. 06 -65- Entegra EXP5000 PFD
4.8 Loss of Communication with Autopilot
If autopilot data becomes unavailable, the autopilot annunciators are
removed from the display and a message with the text, “NO
COMMUNICATION WITH AUTOPILOT,” is displayed at the top of the
PFD (Figure 22).
Figure 22. Autopilot Data Unavailable Message
Note: It is normal to see this message when the PFD is turned on before the
autopilot, but it should not persist for any longer than 20 seconds after the
autopilot is turned on. If the message appears after the autopilot has
initialized, cycle power to the PFD. If the problem persists, contact an
Avidyne Entegra Certified Service Center as soon as practical.
Vista de pagina 70
1 2 ... 66 67 68 69 70 71 72 73 74 75 76 ... 89 90

Comentarios a estos manuales

Sin comentarios